Supplier & stockist · Busbars & Nickel Strip
Copper Busbar — Manufacturer & Supplier in Mumbai
Copper Busbar to ASTM B187 from Ramani Steel House, manufacturer and supplier in Mumbai since 1974. Request current sizes, stock and pricing.
Copper Busbar is a high-conductivity copper bar for pack-level current paths. It is supplied to ASTM B187 in bar, busbar and rod. Ramani Steel House supplies it from Mumbai, India — from stock and against order, cut to size, with the mill test certificate for the heat supplied.
Page last updated .
High-conductivity copper bar for pack-level current paths, where the conductor carries the combined output of many parallel groups rather than the current of a single cell.


Copper Busbar supply information
| Grade | Copper Busbar |
|---|---|
| Standards | ASTM B187ASME SB-187 |
| Material family | Busbars & Nickel Strip |
| Forms | Bar · Busbar · Rod |
| Processing | Stamping · Punching · Laser Cutting · Waterjet Cutting · Slitting · Shearing · Band Saw Cutting |
| Traceability | Mill test certificate with every order · AS9120:2018 certified |
| Supplied as | Supplier · Stockist · Stockholder · Distributor · Importer · Exporter — Mumbai, India |
| Availability | Ex-stock and against order — confirmed on enquiry |
| Cut to size | Stamping · Punching · Laser Cutting · Waterjet Cutting — no minimum length |
Chemical composition, mechanical properties and dimensional tolerances are supplied against the applicable standard with each order. Ask us for the datasheet and test certificate for the exact form and size you need.
Also specified as
- Copper Busbar
- Copper Busbar Rod
- ASTM B187
- ASME SB-187
The same material under the names and designations buyers order it by. Quote any one of them and we will supply against it.
Copper Busbar bar surface finishes
Round bar is quoted by finish as well as by diameter, and the finish changes both the surface and how closely the diameter is held. These are the standard designations — tell us which you need and we will confirm what is available in this grade and size.
| Code | Finish | How it is produced | What you get |
|---|---|---|---|
| HF | Hot finished | Hot rolled or forged, then straightened. | Dark, scaled surface with the widest diameter tolerance. The usual choice where the bar will be machined all over. |
| HRAP | Hot rolled, annealed and pickled | Hot finished, then annealed and pickled to remove mill scale. | Clean matt grey surface with the scale chemically removed, so corrosion resistance is restored. Tolerance as hot finished. |
| ST | Smooth turned (peeled) | Hot finished bar turned or peeled all over on a machine. | Bright machined surface, decarburised and scaled layer removed, closer and more consistent diameter than hot finished. |
| PR | Peeled and reeled | Peeled, then reeled (roller straightened and burnished). | Peeled surface improved by reeling, with better straightness — specified where the bar feeds automatic machines. |
| CD | Cold drawn | Drawn cold through a die. | Bright surface, close diameter tolerance, and higher strength and hardness from the cold work. Common on smaller diameters. |
| BD | Bright drawn | Cold drawn, sometimes with a further light draw or polish. | The brightest of the drawn finishes. Used where the bar's surface is the finished surface. |
| CG | Centreless ground | Turned or drawn, then ground between centreless wheels. | The closest diameter tolerance and best roundness of the standard finishes. Specified for shafts, pins and anything running in a bearing or seal. |
| PL | Polished | Ground, then polished. | Lowest surface roughness, for sealing faces, hygienic service and visible parts. |
Copper Busbar applications
- EV battery packs
- Module-to-module and pack-level current paths, and connections to the main contactor.
- Energy storage
- Distribution busbars inside stationary storage cabinets.
- Electrical distribution
- Switchgear, panel boards and earthing connections.
Industries that specify Copper Busbar
- Automotive Alloys & Busbars
Pack-level current paths in electric vehicles.
- EV Battery Nickel Strip & Busbars
Module-to-module and pack-level current paths.
- Electrical Nickel & Copper Conductors
Switchgear, panel boards and distribution busbars.
Copper Busbar inspection & test certificates
AS9120:2018
The aerospace standard written specifically for stockist distributors. It covers traceability, counterfeit-part prevention and records retention — the controls an aerospace buyer audits before approving a supplier.
Download certificate (PDF)ISO 9001:2015
The general quality management standard, covering how orders, inspection and non-conformances are controlled.
Download certificate (PDF)
Material is supplied with its mill test certificate, reporting the chemistry and mechanical properties of the heat you receive — which is what the limits in the tables above are checked against. If your order needs third-party inspection, additional testing or a specific certificate type, say so with the enquiry and we will confirm what we can arrange before you order.
Copper Busbar — frequently asked
- When should a pack use a copper busbar instead of nickel strip?
- They do different jobs. Nickel strip connects cell to cell, because it spot welds to the cell can and resists corrosion at the joint. Copper busbar carries the pack-level current, where copper's much higher conductivity matters and nothing is being welded to a cell can. Most packs use both.
Know your exact specification?
Send the grade, form, dimensions and quantity and we will quote against it directly.
Send a detailed enquiry →